Tải bản đầy đủ - 0 (trang)
Figure H.1 — Location of hardness tests

Figure H.1 — Location of hardness tests

Tải bản đầy đủ - 0trang

ISO 3183:2007(E)



API Specification 5L/ISO 3183



Dimensions in millimetres (inches)



--``,````,`,,,`,,```,`,`,`,,`-`-`,,`,,`,`,,`---



c) HFW pipe

a



Weld centreline.



b



0,75 mm (0.03 in) from fusion line.

1 t from fusion line.



c

d

e



1,0 mm (0.04 in) spacing in visible HAZ.

From inside and outside surfaces.



Figure H.1 — Location of hardness tests (continued )



Copyright American Petroleum Institute

Provided by IHS under license with API

No reproduction or networking permitted without license from IHS



© ISO 2007 – All rights reserved



115

Licensee=US mvd from 2458000/5940240030, User=Melo, Cynthia

Not for Resale, 05/19/2009 17:41:28 MDT



115



ISO 3183:2007(E)



API Specification 5L/ISO 3183



Annex I

(normative)

Pipe ordered as “Through the Flowline” (TFL) pipe



I.1 Introduction

This annex specifies additional provisions that apply for pipe that is ordered as TFL pipe [see 7.2 c) 53)].



I.2 Additional information to be supplied by the purchaser

The purchaser order shall indicate which of the following provisions apply for the specific order item:

a)



type of length (see I.4);



b)



supply of jointers (see I.4).



I.3 Dimensions and grades

TFL pipe shall be SMLS or longitudinal seam pipe in the specified outside diameters, specified wall

thicknesses and grades given in Table I.1.



I.4 Lengths and jointers

Unless otherwise agreed, TFL pipe shall be furnished in double random lengths with no jointers.



I.5 Drift test

I.5.1

Each length of TFL pipe shall be tested throughout its entire length with a cylindrical drift mandrel

conforming to the dimensions given in Table I.2. During the drift test, the pipe shall be properly supported to

prevent sagging and shall be free of all foreign matter.

I.5.2

The leading edge of the drift mandrel shall be rounded to permit easy entry into the pipe. The drift

mandrel shall pass freely through the pipe with a reasonable exerted force appropriate for the mass of the drift

mandrel being used for the test.



I.6 Hydrostatic test

Each length of TFL pipe shall be hydrostatically tested in accordance with the requirements of 9.4, except that

the minimum test pressures shall be as given in Table I.1.

NOTE

The test pressures given in Table I.1 represent the lesser of 68,9 MPa (9 990 psi) and the pressures derived

using Equation (6), using a hoop stress, S, equal to 80 % of the specified minimum yield strength of the pipe.



--``,````,`,,,`,,```,`,`,`,,`-`-`,,`,,`,`,,`---



Copyright American Petroleum Institute

Provided by IHS under license with API

No reproduction or networking permitted without license from IHS



116



116

Licensee=US mvd from 2458000/5940240030, User=Melo, Cynthia

Not for Resale, 05/19/2009 17:41:28 MDT



© ISO 2007 – All rights reserved



ISO 3183:2007(E)



API Specification 5L/ISO 3183



I.7 Pipe markings

In addition to the pipe markings required in 11.2, the product specification level designation shall be followed

by the letter “I” to indicate that Annex I applies.



Table I.1 — Dimensions, masses per unit length and test pressures for TFL pipe

Specified

outside diameter

D

mm (in)



Specified wall

thickness

t

mm (in)



Calculated

inside diameter

d

mm (in)



Grade



60,3 (2.375)



4,8 (0.188)



50,7 (1.999)



73,0 (2.875)



11,1 (0.438)



73,0 (2.875)



Mass per unit

length

kg/m (lb/ft)



Hydrostatic test

pressure

(minimum)

MPa (psi)



L390 or X56



6,57 (4.40)



49,2 (7 140)



50,8 (1.999)



L390 or X56



16,94 (11.41)



68,9 (9 990)



5,5 (0.216)



62,0 (2.443)



L390 or X56



9,16 (6.14)



46,5 (6 740)



88,9 (3.500)



13,5 (0.530)



61,9 (2.440)



L390 or X56



25,10 (16.83)



68,9 (9 990)



101,6 (4.000)



19,1 (0.750)



63,4 (2.500)



L415 or X60



38,86 (26.06)



68,9 (9 990)



101,6 (4.000)



12,7 (0.500)



76,2 (3.000)



L290 or X42



27,84 (18.71)



57,9 (8 400)



101,6 (4.000)



12,7 (0.500)



76,2 (3.000)



L415 or X60



27,84 (18.71)



68,9 (9 990)



101,6 (4.000)



6,4 (0.250)



88,8 (3.500)



L485 or X70



15,02 (10.02)



48,6 (7 050)



114,3 (4.500)



19,1 (0.750)



66,1 (3.000)



L360 or X52



44,84 (30.07)



68,9 (9 990)



114,3 (4.500)



7,1 (0.281)



100,1 (3.938)



L485 or X70



18,77 (12.67)



48,0 (6 960)



ρl



Table I.2 — Drift mandrel dimensions



--``,````,`,,,`,,```,`,`,`,,`-`-`,,`,,`,`,,`---



Specified outside diameter of the pipe

D

mm (in)



Length



Diameter



< 88,9 (3.500)



1 066 (42)



d − 2,4 (0.093)



W 88,9 (3.500)



1 066 (42)



d − 3,2 (0.125)



NOTE



Mandrel dimensions

mm (in)



d is the calculated inside diameter of the pipe (see Table I.1).



Copyright American Petroleum Institute

Provided by IHS under license with API

No reproduction or networking permitted without license from IHS



© ISO 2007 – All rights reserved



117

Licensee=US mvd from 2458000/5940240030, User=Melo, Cynthia

Not for Resale, 05/19/2009 17:41:28 MDT



117



ISO 3183:2007(E)



API Specification 5L/ISO 3183



Annex J

(normative)

PSL 2 pipe ordered for offshore service



J.1 Introduction

This annex specifies additional provisions that apply for PSL 2 pipe that is ordered for offshore service [see

7.2. c) 54)].

NOTE

This annex does not include requirements for specialized tests for pipe intended for applications such as pipe

reeling or for pipe that will experience high (> 0,5 %) total, single event strain during installation. For such applications,

additional testing can be necessary to prove the suitability of the pipe and the purchaser might need to supplement the

requirements of this International Standard with other appropriate provisions (e.g. see DNV-OS-F101 [14]).



J.2 Additional information to be supplied by the purchaser



a)



steel casting method for strip or plate used for the manufacture of welded pipe (see J.3.3.2.1);



b)



ultrasonic inspection of strip or plate for laminar imperfections (see J.3.3.2.4);



c)



supply of helical-seam pipe containing strip/plate end welds (see J.3.3.2.5);



d)



chemical composition for intermediate grades (see J.4.1.1);



e)



chemical composition for pipe with t > 25,0 mm (0.984 in) (see J.4.1.2);



f)



carbon equivalent limit for steel Grade L555QO or X80QO (see Table J.1);



g)



chemical composition limits [see Table J.1, footnote d)];



h)



acceptance criteria for tensile properties if determined at other than room temperature (see J.4.2.2);



i)



for Grade L555QO or X80QO and L555MO or X80MO pipe, a lower maximum tensile strength limit may

be agreed [see Table J.2, footnote b)];



j)



minimum average length other than 12,1 m (39.7 ft) and/or different range (see J.6.3);



k)



diameter and out-of-roundness tolerances for SMLS pipe with t > 25,0 mm (0.984 in) [see Table J.3,

footnote b)];



l)



use of inside diameter to determine diameter and out-of-roundness tolerances for non expanded pipe

with D W219,1 mm (8.625 in) [see Table J.3, footnote c)];



m) hardness test of the pipe body seam weld and HAZ of EW and SAW pipe (see Table J.7);

n)



CTOD testing (see J.8.2.2 and Table J.7);



o)



use of the ring expansion test for transverse yield strength determinations [see Table J.8, footnote c)];



p)



additional longitudinal tensile testing for deep-water pipelay [see Table J.8, footnote d)];



Copyright American Petroleum Institute

Provided by IHS under license with API

No reproduction or networking permitted without license from IHS



118



118

Licensee=US mvd from 2458000/5940240030, User=Melo, Cynthia

Not for Resale, 05/19/2009 17:41:28 MDT



© ISO 2007 – All rights reserved



--``,````,`,,,`,,```,`,`,`,,`-`-`,,`,,`,`,,`---



The purchase order shall indicate which of the following provisions apply for the specific order item: